Thermal3 Parameter
med <media index> strokeoffset

Variables media index Selects the media index from 0 to 63.

Description The NVS parameters med <media index> strokeoffset and med <media index> strokewidth configure the pixels that will be used for plotting. The NVS parameters lvd blockeroffset and lvd blockerwidth configure the pixels that are not physically blocked. The NVS parameter med <media index> strokeoffset determines the pixel offset of the stroke ( from the home side ).

There are several requirements for the stroke configuration as follows:
  • The offset and width of the configured stroke must be a multiple of eight.
  • The configured stroke must not exceed the maximum number of pixels.
  • The configured stroke must not be phsyically blocked.

Type Integer

Default Value 8

Range 0 to 456

Related Documents PARAMETER: med <media index> strokewidth
PARAMETER: lvd blockeroffset
PARAMETER: lvd blockerwidth

Applies to: THERMAL3
Access: FIELD
Modified: Wed Jul 16 04:28:36 2008
Updated: Wed Jul 16 04:52:23 2008
Module: MED