Thermal3 Parameter
med <media index> beamslope <polarity>

Variables media index Selects the media index from 0 to 63.
polarity Selects the polarity from 0 to 1 ( 0 is high, 1 is low ).

Description The beam slope defined by the copy of the media parameters where the copy is selected by the media index. When performing a beam-balance, the beam slope specifies the target profile slope.

The beam-balance algorithm will adjust the stroke values to create a linear relationship between the pixel power and the pixel number. The value of the slope specifies the difference between the pixel power at the edges of the swath expressed as a percentage of the maximum pixel power.

Type Real

Default Value 0.000 %

Range -50.000 to 50.000 %

Related Documents COMMAND: bbs balance
PARAMETER: med <media index> beamcurve <polarity>
PARAMETER: med <media index> beampiston
PARAMETER: med <media index> stroke <polarity / spot quad>
PARAMETER: med <media index> scorr <polarity / spot quad>

Applies to: THERMAL3
Access: FIELD
Modified: Wed Jul 16 04:28:36 2008
Updated: Wed Jul 16 04:52:23 2008
Module: MED