Thermal3 Parameter
med <media index> stroke <polarity / spot quad>

Variables media index Selects the media index from 0 to 63.
polarity / spot quad Selects the spot quad from 0 to 231 ( 0 to 115 are high, 116 to 231 are low ).

Description The stroke table defined by the copy of the media parameters where the copy is selected by the media index. When performing a plot, the pixel levels and thus the pixel powers are configured using the stroke table.

If successful, a beam-balance will calculate and initialize the stroke table. The target profile is determined by the NVS parameters med <media index > beamslope <polarity>, med <media index> beamcurve <polarity>, med <media index> beampiston and med <media index> scorr <polarity / spot quad>.

Type Integer

Default Value 0

Range 0 to 255

Related Documents COMMAND: bbs balance
PARAMETER: med <media index> beamslope <polarity>
PARAMETER: med <media index> beamcurve <polarity>
PARAMETER: med <media index> beampiston
PARAMETER: med <media index> scorr <polarity / spot quad>

Applies to: THERMAL3
Access: FIELD
Modified: Wed Jul 16 04:28:36 2008
Updated: Wed Jul 16 04:52:22 2008
Module: MED