Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Autofocus tracking error with artifacts


Product

 

Thermal 3 head


Symptoms

 

Autofocus tracking error with artifacts


Cause

 

Some heads have a longer than expected autofocus system delay, which can cause an autofocus tracking error. The tracking error has not been seen in the field to date and has not been reproduced under normal operating conditions; however, since the potential for tracking errors exists on some heads, a fix has been provided in firmware version 1.03.08.


Solution

 
  • Upgrade the head firmware to version 1.03.08, available from the Firmware release page.

Technical contact(s)
 

Kurt Shelton

Submitted by
 

Kurt Shelton

Date submitted
 

01 Dec 2006


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.