Error |
|
[01403] Failure verifying the BSDL data / JTAG error(s)
|
|
Symptoms |
|
The error may occur on the first plot after the device has been sitting idle for a while. For example, the first plot on the first day of the work week.
|
|
Cause |
|
The error occurs because a satellite board was not initialized properly.
- The firmware can detect this and typically resets the board until the satellite board comes online.
- If this does not occur, the device may have overheated. If the chiller has failed or the chiller water is low, this can also initiate this error.
|
|
Solution |
|
- Complete a hard reset of the head.
- If the head begins functioning normally, continue running and monitor the frequency of error 1403.
- If the head does not return to normal function:
- Check that the chiller is operational.
- Check that the water level in the chiller is correct.
- Check that all satelite boards are valid. Type the command
Th3>>sat ver and check that all boards are listed as (accepted).
- Reset the head until it returns to normal operation or until a replacement is available.
|
|
See also |
|
Sample readout for Th3>>sat ver:
TH3 > sat ver
Expected-Detected Satellite Versions
Id Type HwVer Configuration
-------------------------------------
[0] NPE 02-02 02-02 02.00-02.03 (accepted)
[1] ACT 01-01 02-02 01.00-01.05 (accepted)
[2] PBP 04-04 02-02 01.00-01.00 (accepted)
[3] IBS 03-03 02-02 01.00-01.00 (accepted)
[4] DBP 06-06 03-03 01.00-01.00 (accepted)
[5] WLC 05-05 02-02 00.00-00.04 (accepted)
[6] RFE 07-07 02-02 01.01-01.04 (accepted)
[7] LVDU 08-08 03-03 03.00-03.01 (accepted)
[8] LVDL 09-09 02-02 03.00-03.01 (accepted)
*** Command Success ***
|
|