Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Error appears when running scripts on Lotem 800 II with Service Shell 2.5


Product

 
  • Service Shell 2.5
  • Lotem® 800 II

Error

 

Error reading head media on the master


Symptoms

 

When trying to run any of the Quantum series scripts (focus, power, slope, curve, and so on) the error message Error reading head media on the master displays.


Cause

 

One or more of the defined media names is using an illegal character, such as a period (.) or underscore (_).


Solution

 
  1. Shut down the Lotem application.
  2. Start Service Shell and change any media names that are using illegal characters. Do this in both the MCE (using the Quantum>> prompt) and in the head (type the command TH2>> set med).
  3. Reset the MCE by typing Quantum>> reset.
  4. Start the Lotem application.

Technical contact(s)
 

Jose Delgado

Submitted by
 

Meir Dana

Date submitted
 

30 Jun 2004


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.