On the AIX command line type: lsparent -C -k ent and
press Enter. The following output is displayed:
ent0 Available 04-03
3Com 3C905-TX-IBM Fast EtherLink XL NIC
Where the IBM FE board appears as ent1 and the standard
Ethernet board appears as ent0, see Appendix D.
Configuring Adapter Media Speed (Ethernet / FastEthernet)
The default adapter configuration uses Autodetect for
10/100BaseTX (Ethernet / FastEthernet). The board senses the port speed on the attached
Hub / Switching Hub and configures itself automatically on each reboot
The Autodetect was tested with the following 3com network
devices:
LANplex2500
Switch1000
Switch3000
LinkBuilder FMS 100
It is possible to disable the auto speed detect and to set
the board speed manually as follow:
On the AIX command line execute sequence: Smit devices-> Communication -> Ethernet Adapter-> Adapter-> Change / Show
Characteristics of an Ethernet Adapter
and press Enter.
In the Media Type field you can set the adapter speed to one
of the following:
10BaseT
100BaseTX
Auto
The IBM PCI FastEthernet adapter supports FullDuplex
connection when connected directly to one of the following networking devices:
LANplex2500
Switch1000
Switch3000.
It is recommended to use FullDuplex also when the board is
installed on Ripro Server/Archiver.
In the default configuration the FullDuplex is disabled.
Please note that it is a essential to configure FullDuplex
on both ends.
For additional information on FullDuplex and FullDuplex
configuration see Appendix A - Full Duplex..
IP Configuration
Use Smit to configure en0 with the station IP address (IP
address, subnet musk and default gateway address - you can see the station IP address in
/etc/hosts): Smit TCP/IP -> Minimum Configuration & Startup and press Enter
Select en0 and press Enter
It the IP parameters dont appear, fill in the required
parameters (IP address, subnet musk and default gateway address - IP address must appear,
the other two parameters are optional according to the site network configuration).
Press Enter.
AppleTalk Configuration
AppleTalk will automatically run on the new adapter.
Reboot the E30.
Appendix A - Full Duplex
Full Duplex can be configured between the IBM FastEthernet
PCI and the following products:
Switch1000: On the two FastEthernet ports
Switch3000: On all nine FastEthernet ports
LANplex2500: On the FastEthernet module
Please note that it is a essential to configure FullDuplex
on both ends.
Full Duplex allows simultaneous transmission and reception of
data . This is not possible on a shared repeater segment (because all devices attached to
the repeater share a single, common transmit and receive channel).
Full Duplex can be used on point-to-point links where switch
ports are directly connected to each other. When Full Duplex is activated, both ends can
transmit and receive simultaneously, the collision detect mechanism is not activated.
Full Duplex will give the potential to increase the
throughput on a Fast Ethernet port beyond 100 Mbps (up to 200 Mbps). This will be most
useful on inter-switch and server links which carry significant two-way traffic.
Even for less then 100Mbps bi-directional traffic the Full
Duplex is more efficient (than Half Duplex) since it is possible to "receive and
transmit simultaneously on the link".
The first advantage is that a switch can receive data from
another switch while simultaneously transmitting data, theoretically allowing up to 100
Mbps (Fast Ethernet) in each direction.
In practice the benefit is lower than a doubling of
bandwidth, owing to the half-duplex nature of the traffic.
The FastEthernet ports on the Switch1000 and Switch3000
support Half & Full Duplex. The Full Duplex can be used when the port is connected to
LP2500 FE port, to Switch1000 FE port or to all Switch3000 ports.
Full Duplex set up
On the AIX command line execute sequence: Smit devices-> Communication -> Ethernet Adapter-> Adapter-> Change/Show
Characteristics of an Ethernet Adapter
and press Enter
In the Full Duplex field you can set the adapter speed to one of the following:
no
yes
Auto
On the AIX it is impossible to change the configuration of
the IBM PCI FE board when the device is busy.
When you try to change the configuration on busy device you
will get the following error: Method error (/usr/lib/methods/chgv3boom):
0514-062 Cannot perform the requested function because the specified device is busy.
To over come the above situation you should do the following
(only on a monitor attached to the station and not from a remote station since this
process involves disconnecting from the network):
Detach en0.
On the AIX command line execute sequence : Smit tcpip -> Further Configuration -> Network Interfaces -> Network
Interface Selection -> Change / Show Characteristics of a Network Interface and press Enter.
Select en0 and press Enter.
Change the Current STATE field to detach and
press Enter.
Disable Helios EtherShare auto start up at reboot by editing
the file /etc/inittab using "vi" and enter colons at the beginning of
the "start-atalk line"
: rcatalk:2:wait:sh /usr/local/es/start-atalk
Reboot the machine.
Change the IBM PCI FastEthernet adapter set up
Attach en0
On the AIX command line execute sequence : Smit tcpip -> Further Configuration -> Network Interfaces -> Network
Interface Selection -> Change / Show Characteristics of a Network Interface and press Enter.
Select en0 and press Enter.
Change the Current STATE field to up and press Enter.
Enable Helios EtherShare auto start up at reboot by edit the
file /etc/inittab using "vi" and remove the colons at the beginning of
the "start-atalk line"
Reboot the machine.
Appendix C - The error message: Requisite
Failures
Selected Filesets:
The following is a list of filesets that you asked to install. They cannot be installed
until all of their requisite filesets are also installed. See subsequent lists for details
of requisites.
devices.pci.b7105090.diag 0.20.0.0
# 3Com 3C905-TX-IBM Fast Ether...
devices.pci.b7105090.rte 0.20.0.0
# 3Com 3C905-TX-IBM Fast Ether...
Missing Requisites:
The following filesets are required by one or more of the selected filesets listed above.
They are not currently installed and could not be found on the installation media.
devices.mca.8ef5.com 4.1.0.0
# Base Level Fileset
<< End of Failure Section >>
The above error could happen only If you perform a cold start
after replacing the IBM Standard Ethernet board with the IBM FE board.
This issue will be resolved in future version of the Ripro Server, on the Brisque this
issue is resolved in version 2.0.37.
To overcome this error you should load from CD-ROM #1 (AIX
4.1.4 or 4.1.5 depending on the station configuration) using the sequence: Smit-> Software Installation and Maintenance-> Install and Update Software->
Install/Update Selectable Software (Custom Install)-> Install Additional Device
Software
Select cd0 as the input device and load the missing
lpp (devices.mca.8ef5.com).
Appendix D
The above situation appears where the FastEthernet driver was
already installed on the system when the FastEthernet board was installed. To correct this
situation perform the following:
On the AIX command line type: rmdev -d -l ent0
rmdev -d -l ent1
rmdev -d -l en1
rmdev -d -l et1
cfgmgr and press Enter.