SCSI Primer

This primer is intended to help people understand the different SCSI signalling used in Creo’s product lines.

Types of SCSI

SCSI bus termination

A rule of thumb about SCSI termination is that ONLY the two devices at the two end of the chain need to be terminated, all devices in the middle MUST NOT have termination turned on. Ensure that the correct type (Single-Ended, LVD or Differential) terminator is installed.

SCSI power up bus negotiation and SCSI Device type and Data Transfer mode:

SCSI data flow between the Workstation and the TS cardcage:

Once all of the above critiria are met, ONLY the Raster data (bitmap, 10101010101....) is passed from the RIP to the SCSI Printer device (through NT SCSI controller driver such as AIC78xx.SYS for the Adaptec 2944UW controller, to SCSIPRNT.SYS, then to SCSIPORT.SYS out to the wire).

The raster data reach the TS backplane, through the DPE (or now a day FDPE) which buffer the incoming raster data into its two buffers (one buffer being emptied to the laser head while the other is being filled up) to allow it to be able to continually process data at high speed as long as the Workstation can supply the data at the sustain rate, which:

Troubleshooting SCSI problem connected to output devices:

  1. Check for physical things that can be visually inspected, SCSI pin bend in the cable connectors, between intermediate cables (i.e. from the cardcage backplane to the platesetter connector panel, I’m not sure if the TS still has the inter-connecting SCSI cable, best if it’s no longer used).
  2. Ensure the approved SCSI card is installed (i.e. 2944UW/DG for DG server and 2944UW/DELL for DELL server).
  3. Ensure all NT drivers (AIC78xx.SYS, SCSIPRNT.SYS and SCSIPORT.SYS) are started successfully with the correct version, and that the "Creo Platesetter 3244" device appears after the appropriate SCSI controller (i.e. Adaptec AHA290x/291x/294x/394x/4944/AIC78xx PCI SCSI Controller (NT 4.0)) in Control-Panel’s "SCSI Adapters" applet.
  4. Start up the Workstation software and ensure there's no SCSI error reported from the software console.
  5. Test plot a simple file to a dummy plate to make sure the SCSI sub-system is working fine.
  6. If 1 to 5 is carried out without problem, then plot the problematic file and monitor for error.

Questions? Contact Keith Chan.