Product |
|
Dell PowerEdge 2300, 2400, 2500, 2550, 4300,
4350, 4400, 6300, and 6350 |
Platform |
|
Intel
|
Operating system |
|
Microsoft® Windows NT® Server, Microsoft Windows® Server Family
(Windows 2000 Server and Windows 2000 Advanced Server)
|
|
Machines affected |
|
PowerEdge 2400, 2500, 2550, 4400, 6400, and 6450
|
|
Error |
|
From Windows 2000 Event Viewer System Log:
Event Type: Error
Event Source: Dell OpenManage Server Agent
Event Category: None
Event ID: 1104
Date: 6/18/2002
Time: 1:17:10 PM
User: N/A
Computer: DB008
Description:
Fan sensor detected a failure value
Sensor location: Hard Drive Fan 1
Chassis location: Main System Chassis
Previous state was: OK (Normal)
Fan sensor value (in RPM): 57122
Event Type: Warning
Event Source: Dell OpenManage Server Agent
Event Category: None
Event ID: 1306
Date: 6/18/2002
Time: 1:17:09 PM
User: N/A
Computer: DB008
Description:
Redundancy lost
Redundancy unit: System Cooling Unit
Chassis location: Main System Chassis
Previous redundancy state was: Normal
Number of devices required for full redundancy: 5
This error is repeated over and over again.
|
|
Solution |
|
- Ensure that Dell OpenManage Server Agent 4.3.0 is installed. To determine which version of the agent is installed:
- Search for the DCESM.sys file. It will likely be in the D:\WINNT\system32\drivers folder.
- Right-click the file, and then click Properties.
- In the Properties dialog box, click the Version tab. The version information displayed should be similar to the following:
File Version: 4.30.xxx.x
- Download and install the update (OMSA430B-A00.exe) for Dell OpenManage Server Agent 4.3.0.
Note: This update only works with Dell OpenManage Server Agent 4.3.0.
|
|
See also |
|
Dell Support
|
|
PR # |
|
1798
|
|
Additional info |
|
This Update package 4.3.0B is for Server Agent version 4.3.0 only.
|
|
Technical contact(s) |
|
Gary Tanaka
|
Submitted by |
|
Gary Tanaka
|
Date submitted |
|
18 Jun 2002
|