Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


SCSI timeouts in Event Viewer with U320 drives


Product

 

Dell PowerEdge 1600SC


Error

 

"The device, \Device\Scsi\symmpi1, did not respond within the timeout period."

  • Source: symmpi
  • Type: error
  • Event ID: 9

"An error was detected on device \Device\HardDisk0\DR0 during a paging operation."

  • Source: disk
  • Type: Warning
  • Event ID: 51.

This error may vary in the HardDisk number and DR number.


Symptoms

 

SCSI timeouts.


Cause

 

Problem with BIOS version A08 when used with U320 drives. These include IBM/Hitachi, Ultrastar, and Maxtor.


Solution

 

Update the system BIOS to A09. Available at http://support.dell.com/ or on the TechPlanet downloads page.


Technical contact(s)
 

Richard Brooks

Derek Braendel

Submitted by
 

Richard Brooks

Date submitted
 

05 Nov 2003


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.