Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Calibrating a Qualstar 4000 Library


Description

 This procedure describes how to calibrate a Qualstar 4000 library.

Product

 Qualstar 4000 Library

Symptoms

  Sometimes it is necessary to execute the CALIBRATE command. For example, the TLS must be recalibrated after new hardware is installed or if the model number is changed.

Solution

 

This procedure is from the Qualstar Technical Services manual.

  1. Enable the Private menu using "Update" as the password. For more information, refer to the Qualstar Technical Service Manual, Section 5.3.2.


  2. Choose CALIBRATE. You will be asked to withdraw all of the tapes from the library (you can do this from the front door). Ensure that the empty magazine(s) are in place. For more information, refer to the Qualstar Technical Service Manual, Section 5.4.1.


  3. Clear the password after the calibration to prevent unauthorized access to the Private commands. For more information, refer to the Qualstar Technical Service Manual, Section 5.3.3.


Technical Contact(s)
 

Lev Weissman


Submitted by
 

Garry Guan


Date Submitted
 

10 Jan 2005


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.