Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Brisque

Using the Brisque as remote terminal for the Realist Proofer

Dov Vainer
10-Oct-99

The following text describes how to use the Brisque as remote terminal for the Iris Realist Proofer.
As of 5/11/99 a new RS232 cable will be added to the Brisque to Iris proofers I/F kit cat # 510K50586A.
For all the previous installations the cable can be order via the local stock.
The cable's catalog number is 610S40440.

Diagnostic from local Brisque that connected directly to the Iris proofer with RS232 cable

  1. Verify that the RS-232 cable cat # 610S40440 is connected between com1 socket on the Brisque to The RS-232 socket in the Iris proofer.
  2. On the Brisque type:
    cd /scitex/version/utiles/modem
  3. Type kermit

  4. Type set line /dev/tty0

  5. Type set speed 9600

  6. Type c

  7. Now you are connected to the Iris.

  8. To stop the connection type ^\ (Ctrl+Backslash) then press c.

  9. Type exit to quit kermit

Diagnostics from remote location using modem

  1. Verify with the customer what is the Hostname of the Brisque that connected to the Iris with RS-232 cable.
  2. Login to the site via modem.
  3. Switch (if necessary) the connection to the proof station using telnet and the Hostname.
  4. Use steps 2- 9 from the previous description.
  5. Type exit twice to stop the telnet connection and the modem connection.

    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.