Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Replacing a failed user disk on the Brisque (assumes the disk is inoperable)


Product

 
  • Brisque 3.0.38
  • Brisque 4.0.97

Platform

 

Brisque 3.0.38

  • E30 - Victory
  • 43P-140 Tiger 1
  • 43P-150 Tiger 2
  • F50 - Wildcat (2 and 4 CPUs)

Brisque 4.0.97

  • E30 - Victory
  • 43P-140 Tiger 1
  • 43P-150 Tiger 2
  • F50 - Wildcat (2 and 4 CPUs)
  • 44P-170 Hammerhead
  • 6F1 Condor (2, 4, and 6 CPUs)

Operating system

 

IBM AIX 4.2.1 or IBM AIX 4.3.3


Background

 

The procedure for replacing a failed user disk (dataVolume) on the Brisque is different from the procedure for installing a new disk. All attempts to use SciSmit procedures for adding the replacement disk will fail as svg1 is already being defined.


Procedure

 

For the replacement disk to work:

  1. Export the disk.
  2. Configure the new disk so that the export works properly.
  3. Export it again.
  4. Configure the new disk.

In the prompt type:

Note: The following is for replacing the hdisk1. For all other hdisks, type the appropriate hdisk# at the prompt.

  • SciSmit >> Export a Disk - hdisk1
  • Unix >> exportvg svg1
    This removes svg1. If you don't do this, all procedures added to the new hdisk1 fail because svg1 already exists.
  • UNIX >> cfgmgr
    This adds the hdisk1 since the export disk deleted it.
  • SciSmit >> Configure new disk - hdisk1
    The mount will fail.
  • SciSmit >> Export a Disk - hdisk1
    This will fix the LVM log problems.
  • UNIX >> cfgmgr
    This will add the hdisk1.
  • SciSmit >> Configure new disk - hdisk1

Technical contact(s)
 

Content owner: Eli Cohen

Submitted by
 

Mark Anderson

Date submitted
 

27 Jul 1997