Product |
|
Brisque 4.x
|
Platform |
|
- E30 - Victory
- 43P-140 - Tiger1
- 43P-150 - Tiger2
- F50 - Wildcat (2 and 4 CPUs)
- 44P-170 - Hammerhead
- 6F1 - Condor (2,4 and 6 CPUs)
|
Operating system |
|
IBM AIX 4.2.1 or IBM AIX 4.3.3
|
|
Background |
|
If you attempt to upgrade a Brisque to version 4.0.97 from any other version 4 (especially version 4.0.85), you might fail with the following error message: “There was no data for 4330-08_AIX_ML in the fix database”. In order to prevent this error, prior to migrating from Version 4.0.85 to Version 4.0.97.18, follow the procedure outlined below. |
|
Procedure |
|
- Check the AIX level:
- In Smit, select Software Installation and Maintenance
> List Software and Related Information > List
Installed Software and Related Information > Show
Fix (APAR) Installation Status, then press F4
to show the list.
- If the last AIX level that was loaded is 4330-08_AIX_ML, there is
no need to update AIX. Please continue to step 2.
- If the last AIX level that was loaded is 4330-06_AIX_ML AIX 4330-06 Update, you need to update AIX before Upgrading to 4.0.97.
To update AIX:
- Insert the AIX Add-on CD from 4.0.97.
- Update AIX via SciSmit. Select Software Handling > Update AIX Recommended Maintenance Level.
- Proceed with upgrading to 4.0.97.
- Install the Utils from Brisque Version 4.0.97 CD 1 of 2:
- Exit the Brisque application.
- Login as root and type your password:
ripro.
- Type:
cd /usr/local/es.
- Type:
stop-atalk now.
- Insert the Brisque Product 4.0.97 CD1 into the CD drive.
- Type
smit install_latest and press Enter.
- Press F4 to select the CD-ROM and press Enter.
- Press F4. Select Utils from the list and press Enter.
- Press Enter twice.
- Install Full Version
- Insert the Brisque Product 4.0.97 CD1 into the CD drive.
- Login as root and type your password:
ripro.
- Type
scismit and press Enter. Select Software Handling > Loading Full Software Version.
- Press Enter twice to start the operation.
- Finish the installation by following the instructions on the screen.
- Install the Mandatory Updates
- Insert Product CD 2 of 2 (4.0.97.18).
- Type
scismit and press Enter. Select Software Handling > Update Software Packages.
- Press Enter twice to start the operation.
- Press F4 to list the updates on the CD.
- Select Upd_Brisque4_97_1 and UpdResetBoard and press Press Enter twice.
- At the prompt Are You Sure?, press Enter. The system will automatically reboot when complete.
|
|
See also |
|
Known problem for configurations that include Lotem Quantum
Lotem Quantum PC version 3.5.05 is a prerequisite for Brisque version 4.0.97. After the Brisque upgrade from EP1 (4.0.85+Upds) version to version 4.0.97, you have to calibrate the Lotem Quantum to obtain a full exposable area.
The calibration should be done on the PC Controller, using the "Set gc sshift and mshift" parameters, while setting the following parameters on the Brisque:
- Press Format:
Head/Tail Margins = 6,6
Left/Right Margins = 0,0
- Plate expose:
Offset = 0,0 (without slug/plate ID)
|
|
Technical contact(s) |
|
Content owner: Eli Cohen |
Date submitted |
|