Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


No echo returns to Brisque 3.0.38 from the Dolev x50


Product

 
  • Brisque 3.0.38 Update CD2
  • Dolev x50

Platform

 
  • E30 - Victory
  • 43P-140 - Tiger1
  • 43P-150 - Tiger2
  • F50 - Wildcat (2 and 4 CPUs)

Operating system

  IBM AIX 4.2.1 

Error

 

“No echo received from plotter”


Symptoms

 

There are no echo returns to the Brisque from the plotter during expose on the Dolev x50.


Cause

  This is a known problem and will be fixed in Brisque 4.0.

Solution

 

NOTE: Pre-requisite, Brisque version 3.0.38 with UpdDolev 1.36.

  1. Download pltDc (5.8MB)(click the link to download). This download fixes the problem of no echo returns from the Dolev.

    Copy the file to a dataVolume on the Brisque (for example: /dataVolumes/brisque1.1.0/). The new file should replace the original file with the same name located in /scitex/version/progs.

  2. From the command prompt, perform the following:

  • cd /scitex/version/progs (change directory).
  • cp pltDc pltDc.ver (save the original).
  • cp /dataVolumes/brisque1.1.0/pltDc /scitex/version/progs/ (replace old with new).
  • chmod 755 pltDc (change new file permissions).

Technical contact(s)
 

Dov Vainer

Submitted by
 

Dov Vainer

Date submitted
 

19 Aug 2001