Sending proofs from Brisque 3.0.38 or 4.0 (EP1) to KodakXP causes the error message “TSP don’t fetch data”


Product

 
  • Brisque 3.0.38 Update CD2
  • Brisque 4 (EP1)

Platform

  Version 3.0.38:
  • E30 - Victory

  • 43P-140 - Tiger1
  • 43P-150 - Tiger2
  • F50 - Wildcat (2 and 4 CPUs)

Version 4:

  • E30 - Victory
  • 43P-140 - Tiger1
  • 43P-150 - Tiger2
  • F50 - Wildcat (2 and 4 CPUs)
  • 44P-170 - Hammerhead
  • 6F1 - Condor (2,4 and 6 CPUs)

Operating system

  IBM AIX 4.2.1 or IBM AIX 4.3.3

Error

 

“TSP don't fetch data”


Symptoms

 

While proofing to KodakXP, the above error message appears.


Cause

  This is a known limitation, and will be fixed in Brisque 4 EP2 (4.0.97).

Solution

 

For Brisque 3: Pre- requisites to fix the above problem:

  • Ver 3.0.38 
  • CD option 2 
  • UpdKodakXP 1.27
Download instructions:
  1. Download a compressed tar file fetch_sbi.tar.Z.
  2. Copy the file to one of the dataVolumes.
  3. Save the originals.
  4. Uncompress fetch_sbi.tar.Z.
  5. Run tar -xvf fetch_sbi.tar.

The Patch will replace 3 files:

  • /scitex/version/progs/kodakXP

  • /scitex/version/progs/nsp2kodak

  • /scitex/version/config/unix_pri.ans

The new files will be replaced automatically in the right location with the correct permissions.