Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


In Brisque 3.0.38, the Plate Expose window plate parameters differ from the PC Controller and Configuration window plate parameters


Product

 
  • Brisque 3.0.38 Update CD2
  • Lotem

Platform

 
  • E30 - Victory

  • 43P-140 - Tiger1
  • 43P-150 - Tiger2
  • F50 - Wildcat (2 and 4 CPUs)

Operating system

  IBM AIX 4.2.1 

Symptoms

 

The Plate Expose window compared to the Lotem PC Controller and device Configuration window, displays different plate parameters (like plate size and positive/negative).


Cause

  The Lotem is recognized as Lotem_1 or Lotem_2, instead of Lotem_0 in the Configuration. This can happen when the Brisque connectivity is switched from one Lotem to another. 

This is a known problem and will be fixed in Brisque 4.


Solution

 
  1. Open the Terminal.
  2. Type cd /scitex/version/progs and press Enter.
  3. Type ConfName and press Enter.
  4. Run Configuration and verify that the Lotem is recognized as Lotem_0.

Technical contact(s)
 

Eli Cohen

Submitted by
 

Eli Cohen

Date submitted
 

31 Jan 2000


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.