While exposing imposition two signature jobs from Brisque 3.0.38, incorrect angles may appear on the media


Product

  Brisque 3.0.38 Update CD2 with TSP board

Platform

 
  • E30 - Victory
  • 43P-140 - Tiger1
  • 43P-150 - Tiger2
  • F50 - Wildcat (2 and 4 CPUs)

Operating system

 

IBM AIX 4.2.1


Symptoms

 

Incorrect angles intermittently appear on the media (film or plate) while exposing Imposition jobs with two signatures (back and front).


Solution

 

Prerequisite:
Brisque version 3.038+CD option 2 (UpD 3).

Replace the plateExp, expose, and pltDc files, located at /scitex/version/progs/ with files with the same names from the download site:

To do this:
  1. Download (in binary mode) the files plateExp, expose, and pltDc.
  2. Copy the files to one of the dataVolumes of the Brisque.
  3. Save the original files to:
  4. cd /scitex/version/progs/

    cp expose expose.ver

    cp pltDc pltDc.ver

    cp plateExp plateExp.ver

  5. Copy the new files to:
  6. cp /dataVolumes/brisque.1.0/expose /scitex/version/progs/

    cp /dataVolumes/brisque.1.0/pltDc /scitex/version/progs/

    cp /dataVolumes/brisque.1.0/plateExp /scitex/version/progs/

  7. Check that the permissions of the new files are 755 , if not change them.
  8. Check for the capital/small letters in the names.

Technical contact(s)
 

Dov Vainer

Submitted by
 

Dov Vainer 

Date submitted
 

18 Dec 2000


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.