Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


In the Brisque 3.0.38 to Dolev 800 connectivity, the Resolution Intensity Tables only display 9 resolutions


Product

  Brisque 3.0.38 Update CD2

Dolev 800

Platform

 
  • E30 - Victory

  • 43P-140 - Tiger1
  • 43P-150 - Tiger2
  • F50 - Wildcat (2 and 4 CPUs)

Operating system

 

IBM AIX 4.2.1


Symptoms

 

After loading Brisque on an AIX connected to a Dolev 800, the Resolution Intensity Tables only shows 9 resolutions.


Solution

 

Delete some unused resolutions in order to free some lines in the table.

All the resolutions exist on the Dolev 800.

It is recommended to install the latest Micro version into the Dolev 800 before installing Brisque 3.0.38. The latest Micro version can be found in the Accessory CD from the Brisque software package.


Technical contact(s)
 

Dov Vainer

Submitted by
 

Oren Keinan  

Date submitted
 

04 Jan 2000