When configuring the output device in Brisque 3.0.38, error message 5151 appears


Product

  Brisque  3.0.38 Update CD2

Platform

 
  • E30 - Victory

  • 43P-140 - Tiger1
  • 43P-150 - Tiger2
  • F50 - Wildcat (2 and 4 CPUs)

Operating system

 

IBM AIX 4.2.1


Error

 

Error message 5151


Symptoms

 

The device is in busy mode, the Configuration status shows plotting. Error message 5151 appears during output device configuration.


Cause

 
  1. The last exposure did not finish correctly.
  2. For Brique with VLSI, mon4 is active. For Brisque with TSP, monNsp is active.

Solution

 
  1. For Brisque with VLSI configuration, stop the active Expose process, or reset the board from the Output Device Configuration window.
  2. For Brisque with TSP, run monNsp and then quit, or reset the board from the Output Device Configuration window.
  3. Type q to quit.

Alternatively, reset the Brisque by exiting the Brisque application.


See also

 

See also Brisque to Output Device Config Troubleshooting.


Technical contact(s)
 

Eli Cohen

Submitted by
 

Eli Cohen

Date submitted
 

22 Nov 1999