Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


In Brisque 3.0.38, error message 5154 appears when there is a bad cable connection


Product

  Brisque 3.0.38

Platform

 
  • E30 - Victory

  • 43P-140 - Tiger1
  • 43P-150 - Tiger2
  • F50 - Wildcat (2 and 4 CPUs)

Operating system

 

IBM AIX 4.2.1


Error

 

Error message 5154.


Symptoms

 

Message appears only when the Configuration fails to establish connectivity between device and TSP board.


Cause

  Bad cable connection.

Solution

 
  1. Check the cable connection between the output device and the TSP board.
  2. Verify the output device is in stand by mode.
  3. Check the TSP board diagnostics.
  4. Shut down and then start both the Brisque and the output device.

See also

 

See also Brisque to Output Device Config Troubleshooting.


Technical contact(s)
 

Eli Cohen

Submitted by
 

Eli Cohen

Date submitted
 

22 Nov 1999


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.