Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


In Brisque 3.0.38, if there is no connectivity between the device and the VLSI port, error message 5152 appears


Product

  Brisque 3.0.38

Platform

 
  • E30 - Victory

  • 43P-140 - Tiger1
  • 43P-150 - Tiger2
  • F50 - Wildcat (2 and 4 CPUs)

Operating system

 

IBM AIX 4.2.1


Error

 

Error message 5152.


Symptoms

 

After Brisque has been configured to connect to the device (via the Output Device Configuration window), if there is no connectivity between the device (Lotem and Dolev devices) and the VLSI port, the above error message appears.


Cause

  Bad cable connection between SFL and VLSI.

Solution

 
  1. Verify the connection between SFL and VLSI.

  2. Open the terminal and run mon4 with verify VLSI=OK then q to quit.

  3. Verify the output device is in Stand By mode.

  4. Check the board diagnostics.

  5. Shut down, then start up both the Brisque and the output device.


See also

 

See also Brisque to Output Device Config Troubleshooting.


Technical contact(s)
 

Eli Cohen

Submitted by
 

Eli Cohen

Date submitted
 

22 Nov 1999