Symptoms |
After upgrading the F50 Brisque to Lotem 800 connection to version 3.0, image fetching and rotating is very slow. |
||
Cause |
The Rotation board is not used during image
preparation or rotation.
Once the Brisque application is launched, it is not indicated anywhere whether the Rotation Board is active or not. |
||
Solution |
To ensure that the Rotation board is active, in the Brisque Configuration window, select the appropriate box in Config > Expose > Boards > Use Rotation Board. |
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |