Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Device configuration and Expose does not occur on Brisque 3.0.38 without network connectivity


Product

  Brisque 3.0.38 Update CD2

Platform

 
  • E30 - Victory
  • 43P-140 - Tiger1
  • 43P-150 - Tiger2
  • F50 - Wildcat (2 and 4 CPUs)

Operating system

 

IBM AIX 4.2.1


Symptoms

 

Device configuration and expose does  not occur on a Brisque using a TSP without network connectivity.


Cause

  Missing network connectivity.

Solution

 
  1. Verify that Brisque is connected to the network via the fast Ethernet port.

  2. In the Brisque device configuration window, configure the device.

  3. Send the job to Expose.


Technical contact(s)
 

Eli Cohen

Submitted by
 

Eli Cohen

Date submitted
 

10 Dec 1999


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.