Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


In Brisque 4.0, error message “Machine type is not as expected”, or “No Machine type” appears


Product

  Brisque 4.0

Platform

 

Version 4:

  • E30 - Victory
  • 43P-140 - Tiger1
  • 43P-150 - Tiger2
  • F50 - Wildcat (2 and 4 CPUs)
  • 44P-170 - Hammerhead
  • 6F1 - Condor (2,4 and 6 CPUs)

Operating system

 

IBM AIX 4.3.3


Error

 

Machine type is not as expected.
Or:
No Machine type.


Symptoms

  The reconfigure failed. You cannot modify or delete an output device configuration. You cannot see some of the device information, for example: Device Type.

Cause

 

In case of a failure or crash during expose or plateExpose, the output device configuration files might be corrupted preventing them from operating properly.


Solution

 

Remove the two files that have the output device logical name (as appears in the Output Device Handling window), from the following locations:

/scitex/version/output_config/OutputDevices/

/scitex/version/output_config/DeviceProperties/

Run a new config for the device.


Technical contact(s)
 

Dov Vainer

Submitted by
 

Oren Keinan

Date submitted
 

22 Apr 2002