Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Brisque 3.0.38 and 4.0 Queue Manager not starting because of too many entries


Product

  Brisque 3.0.38 Update CD2 and Brisque 4.0

Platform

 

Brisque 3.0.38

  • E30 - Victory
  • 43P-140 Tiger1
  • 43P-150 Tiger2
  • F50 - Wildcat (2 and 4 CPUs)

Brisque 4.0:

  • E30 - Victory
  • 43P-140 Tiger 1
  • 43P-150 Tiger 2
  • F50 - Wildcat (2 and 4 CPUs)
  • 44P-170 Hammerhead
  • 6F1 Condor (2, 4, and 6 CPUs)

Operating system

 

IBM AIX 4.2.1 or IBM AIX 4.3.3


Symptoms

 

In the RIPro Server and RIPro Archiver, the Queue Manager does not start.


Cause

 

There are too many entries in the Queue Manager.


Solution

 
  1. Exit Brisque.
  2. Login as root.
    rm $SCI_CONFIG/QS_backup
  3. Open Brisque.

Technical contact(s)
 

Lev Weissman

Submitted by
 

Lev Weissman

Date submitted
 

27 July 1997


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.