Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
|||
Product |
Brisque™ 4.0 | ||
Platform |
|
||
Operating system |
IBM® AIX 4.3.3 |
||
|
|
|||
Machines affected |
Lotem™ 800 Quantum platesetter |
||
|
|
|||
Error |
|
||
|
| |||
Symptoms |
Brisque cannot expose a one-bit TIFF that was created as a single-strip by Harlequin® RIP to an output device. Also, Brisque fails to rotate the TIFF file. |
||
|
|
|||
Cause |
This is known problem and is currently under investigation. | ||
|
|
|||
Solution |
Ask the customer to recreate the one-bit TIFF file on the Harlequin RIP as a multiple-strip TIFF file. |
||
|
|
|||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
25 August 2002 |
||