Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


When Staccato is used to expose a copydot file, the quality of the exposed plate is poor, or error 7125 appears during expose


Product

  Brisque™ 4.0.97.23

Platform

 
  • 43P-140—Tiger1
  • 43P-150—Tiger2
  • 44P-170—Hammerhead

Operating system

 

IBM® AIX 4.2.1 or IBM AIX 4.3.3


Machines affected

 
  • Lotem™ Quantum platesetter

  • Screen2Go

  • Trendsetter® 800 platesetter


Error

 

TSP error 7125


Symptoms

 

When a Staccato® screen is used to expose a copydot file, the quality of the exposed plate is poor.

When a Staccato screen is used to expose any job type, Brisque displays error 7125.


Cause

 

A high frequency of color changes occurs with copydot files.


Solution

 

Download and install the compressed staccato.tar.Z patch that contains the updated rbf Staccato files—cmp1_bmp.rbf, cmp2_bmp.rbf and adrg.rbf:

  1. From the FTP location ftp://cilftp.creo.com/pws/brisque/download/, download the staccato.tar.Z patch (31.4 KB) to a Brisque directory.

  2. In Brisque, at the command line prompt, use the CD command to navigate to the directory /scitex/version/plt_extobj/tsp.1.0/Staccato.

  3. Make a backup copy of the cmp1_bmp.rbf, cmp2_bmp.rbf and adrg.rbf files that are saved in the Staccato directory.

  4. Type uncompress staccato.tar.Z, and press Enter.

  5. Type tar -xvf staccato.tar and press Enter. The three rbf Staccato files (cmp1_bmp.rbf, cmp2_bmp.rbf and adrg.rb) are unpacked and copied to the directory /scitex/version/plt_extobj/tsp.1.0/Staccato. The Staccato rbf files are updated.


Technical contact(s)
 

Dov Vainer

Submitted by
 

Dov Vainer

Date submitted
 

23 Dec 2002


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.