Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Error message appears when running errpt command on Brisque


Product

 
  • Brisque® 5.x
  • Brisque 4.x

Platform

 

All platforms

Operating system

 

IBM® AIX® 5.2 or IBM AIX 4.3.3


Error

 

DADF69E4 1029112007 U H SYSINTR UNDETERMINED ERROR


Symptoms

 

When you run the errpt command on a Brisque file to generate a report of logged errors, the following error message and report appears:

DADF69E4 1029112007 U H SYSINTR UNDETERMINED ERROR

LABEL: INTRPPC_ERR
IDENTIFIER: DADF69E4

Date/Time: Tue Oct 29 11:20:07
Sequence Number: 230
Machine Id: 0057C6CA4C00
Node Id: rip4
Class: H
Type: UNKN
Resource Name: SYSINTR
Resource Class: NONE
Resource Type: NONE
Location: NONE

Description
UNDETERMINED ERROR

Probable Causes
SYSTEM I/O BUS
SOFTWARE PROGRAM
ADAPTER
DEVICE

Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES

Detail Data
BUS NUMBER
1001 00CA
INTERRUPT LEVEL
0000 0027


Cause

 

The Rotation board causes this error to appear. This is a known problem and is under investigation.


Solution

Ignore the error message and report that appear. The errpt output doesn't affect the behavior and performance of Brisque.

See also

 

RISC600 Troubleshooting document, pages 8 thru 14.


Technical contact(s)
 

Lev Weissman

Submitted by
 

Lev Weissman

Date submitted
 

12 Jan 2003


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.