Error messages appear in errpt, diagnostics posts an SRN of A05/160, or the system stops responding


Product

 
  • Brisque™ 4.0
  • Brisque Serve 4

Platform

  6F1—Condor (2,4 and 6 CPUs)

Operating system

  IBM® AIX 4.2.1 or IBM AIX 4.3.3, Mac OS® X

Symptoms

 

Error messages appear in errpt, for example, environmental errors, SCSI errors, Power Resumed errors, or Undetermined errors. Diagnostics posts an SRN of A05/160. Occasionally, the system may stop responding.


Cause

 

The IBM 6F1 FRU power supply units (24L1400) do not have the same impedance levels, which causes random EPOWs to occur.

 

Solution

Replace mismatched power supply units with power supply units that have the same FRU and part number as one another.


Technical contact(s)
 

Lev Weissman

Submitted by
  Lev Weissman
Date submitted
 

03 Mar 2003