Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
|||
Product |
|
||
Platform |
|
||
Operating system |
IBM® AIX® 4.2.1 or IBM AIX 4.3.3 |
||
|
|
|||
Error |
|
||
|
|
|||
Symptoms |
After migrating from Brisque 4.0.97.x to version 4.1.76, an error message appears and the improof process fails. |
||
|
|
|||
Cause |
This error appears after migrating from Brisque 4.0.97.x to version 4.1.76 when the printQualityDescr.cnf file (located in /scitex/version/prf_config) overwrites the newer version while the software configuration is being restored. |
||
|
|
|||
Solution |
Perform the Full loading version procedure for version 4.1.76 and Upd1 using SciSMIT. After completing the full loading procedure, save the configuration to the SciSMIT to prevent this problem from happening in the future. The final solution will be included in the next Improof disk. |
||
|
|
|||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
29 Sep 2003 |
||