Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
|||
Product |
|
||
Platform |
|
||
Operating system |
IBM® AIX® 4.2.1 or IBM AIX 4.3.3 |
||
|
|
Symptoms |
System errors appear in the errpt log, or disk failure occurs. Examples of possible system errors include: |
|
|
|
|||
Cause |
Defective SCSI cables used to connect the 73 GB external disk tower to the Brisque workstation cause system errors, or disk failure. |
||
|
|
|||
Solution |
This problem was confirmed by the vendor and will be fixed immediately,
and our stock will be replenished. However, if you experience these error
messages with this configuration only, submit a request to Product Support
for a replacement cable (part number 199D50465, Ultra VHDCI 68 to HPDB
68, 1.5 M). Currently, there are several good replacement cables available. Part Identification You can differentiate between a good cable and a defective cable by its screws. Good cables use steel screws without plastic covers, while defective cables have black plastic covers on the screws. |
||
|
|
|||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
29 Sep 2003 |
||