Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Error messages appear when exposing with MCE devices


Product

 
  • Brisque® 4.1
  • Brisque 5.0
  • Lotem® 800 II family (running on Windows® 2000)
  • Lotem 800 family (running on Windows 95)
  • Magnus™ VLF
  • Trendsetter® Magnus 400II/800II family
  • Trendsetter VLF family

Platform

  All Brisque platforms

Operating system

 

IBM® AIX® 4.3.3, 5.2


Symptoms

 

When exposing with MCE devices, the following errors might appear:

  • Data channel not detected on the Lotem controller or the Print Console
  • No room on buffer timeout (error 5230) on Brisque

Cause

 

The current TMCE Xilinx file on the platesetter device is the cause of this Brisque error.


Solution

 

TMCE Xilinx version 2.23 solves this problem.
The new Xilinx version will be part of:

  • Lotem 800II 3.75.09 Update #2 CD
  • Lotem Quantum version 3.8

Note: For Lotem version earlier than 3.75 running on Windows 95, use TMCE Xilinix version 1.42.


Technical contact(s)
 

Dov Vainer

Submitted by
 

Dov Vainer

Date submitted
 

13 Oct 2004