Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Problem exposing CTs in Brisque 4.1.76+Output_7 and MCE devices with 2 TSPs and Staccato


Product

 
  • Brisque® 4.1.76
  • Trendsetter® MCE
  • Lotem® Quantum 400/800
  • Magnus® VLF
  • Screen2Go

Platform

 

All Brisque 4.x platforms

Operating system

 

IBM® AIX® 4.3.3


Symptoms

 

In Brisque 4.1.76+Output_7, there is problem exposing CTs using Staccato screen on MCE devices that have 2 TSPs.


Solution

 

Solution 1—install Update Output_8:

  1. Download Upd_Brisque41_Output_8.tar to your Brisque.
  2. Install the update as described in the Output_8 Readme.

Solution 2—for Update Output_7, install the adrg4upd7.tar.Z patch:

Save the original file:

  1. Log off from Brisque.
  2. Log on as root and type your password (ripro).
  3. Type: cd /scitex/version/plt_extobj/tsp1.0/Staccato and press enter.
  4. To save the original file, type:
    cp –p adrg.rbf adrg.rbf.org and press enter.

Install the new file:

  1. From a Mac, copy the adrg4upd7.tar.Z patch to /dataVolumes/example.1.0/.updates.
  2. Browse to the patch location and press enter.
  3. Type: uncompress adrg4upd7.tar.Z and press enter.
  4. Type: tar -xvf adrg4upd7.tar and press enter. The file is automatically copied to its designated location.
  5. Type exit and log on as cdesci.

To remove the patch:

  1. Log off from Brisque.
  2. Log on as root and type your password (ripro).
  3. Type: cd /scitex/version/plt_extobj/tsp1.0/Staccato and press enter.
  4. Type: cp –p adrg.rbf.org adrg.rbf and press enter.
  5. Reboot the Brisque.

Technical contact(s)
 

Dov Vainer

Submitted by
 

Dov Vainer

Date submitted
 

30 Nov 2005


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.