In Brisque 5.x, incorrect devices are displayed in the queue


Product

 

Brisque® 5.x

Platform

 
  • 43P-150 (Tiger2)
  • 44P-170—Hammerhead
  • F50—Wildcat (2 and 4 CPUs)
  • 6F1—Condor (2, 4, and 6 CPUs)

Operating system

 

IBM® AIX® 5.2


Symptoms

 

In Brisque 5.x, the devices are listed in the mini-queue, but the Device Info window is empty, and a gray window opens when you select Markers in the Resource Center.


Cause

 

The Exp Java server did not start up at login. The reason for this is because the customer created a hot folder that includes Exp in its name, and the ps -ef lgreg Exp string caused an error in the login script.

Type ps -ef lgrep Exp. The following is displayed:
root 20660 21844 0 09:43:57 lft0 0:00 splr_cog NAME:Lotem_MO_Expose PRINTER:Lotem_MO_Expose KEY:/dataVolumes/brisque13.2.0/MO_Expose/.spooler/key1 TYPE:1
root 21382 21844 0 09:43:57 lft0 0:00 splr_cog NAME:GTO_Expose PRINTER:GTO_Expose KEY:/dataVolumes/brisque13.2.0/GTO_Expose/.spooler/key1 TYPE:1
root 23828 21844 0 09:43:57 lft0 0:00 splr_cog NAME:SM52_Expose PRINTER:SM52_Expose KEY:/dataVolumes/brisque13.2.0/SM52_Expose/.spooler/key1 TYPE:1
root 25342 21844 0 09:43:57 lft0 0:00 splr_cog NAME:SM74_Expose PRINTER:SM74_Expose KEY:/dataVolumes/brisque13. 2.0/SM74_Expose/.spooler/key1 TYPE:1


Solution

 

To solve the problem:

  1. Rename the hotfolders so that they do not include Exp.
  2. Log out from Brisque software and log in again.

Technical contact(s)
 

Lev Weissman

Submitted by
 

Lev Weissman

Date submitted
 

13 Sep 2004