Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
|
||
Platform |
|
||
Operating system |
IBM® AIX® 4.3.3, 5.2 |
||
Error |
When the proof is set to 14.17 x 14.17 dpm, the error message |
||
Symptoms |
The job first goes through pltAutoPipeline, the proof progresses to 100% and then the job fails. |
||
Cause |
The width of the mark that was defined for the job is too narrow. For example, a hairline of 0.125 pt was defined. |
||
Solution |
There are two workarounds to this problem:
|
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
03 Jan 2005 |
||