Error 7155 appears when using Screen2Go with Staccato


Product

 
  • Brisque® 5.x
  • Screen2Go

Platform

 

All Brisque platforms

Operating system

 

IBM® AIX® 5.2


Symptoms

 

TSP error 7155 appears when using Screen2Go with Staccato with devices that have one or two TSP boards.


Solution

 
  1. Verify that there are no spaces in the job names.
  2. Check the network config setting and verify that it is properly defined. For example—a board may be activated although the board is not physically connected.

Technical contact(s)
 

Dov Vainer

Submitted by
 

Dov Vainer

Date submitted
 

05 Sep 2005


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.