Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Excurve calibration is not listed in the Screen2Go device of Device Handling in Brisque 5.1


Product

 

Brisque® 5.1

Platform

 

All Brisque platforms

Operating system

 

IBM® AIX® 5.2


Symptoms

  When performing Excurve calibration for Screen2Go, the Excurve option is not listed in the Device Handling window.

Solution

 

Install the ExcurveForScreen2Go.tar.Z patch:

Pre-requisite: Brisque version 5.1.32

  1. Download ExcurveForScreen2Go.tar.Z.
  2. Follow the installation instructions provided in Excurve for Screen2Go Readme.

Note: This patch will be part of the next Brisque 5.1.32 update.


Technical contact(s)
 

Eyal Eshel

Submitted by
 

Eyal Eshel

Date submitted
 

27 Mar 2006


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.