Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
Product |
|
||
Platform |
6F1 |
||
Operating system |
IBM® AIX® 4.2.1, 4.3.3, 5.2 |
||
Error |
|
||
Symptoms |
On the Brisque 6F1 platform, after an output device was deleted in the Device Handling window, the device cannot be reconfigured and the error message appears. |
||
Cause |
One of the 6F1 CPUs may be defective and the system is working with only 3 CPUs instead of 4 CPUs. Since the system does not recognize the 6F1 platform with 3 CPUs, this configuration is rejected. To verify that this is the cause, open scismit and check if the station information shows only 3 CPUs. |
||
Solution |
Try one of the following 3 options, starting with the first option:
|
||
Technical contact(s) |
|||
Submitted by |
|||
Date submitted |
15 May 2006 |
||