Many retracing occurrences when exposing from Brisque to a Trendsetter MPE platesetter


Product

 
  • Brisque 5.x software
  • Brisque 4.x software
  • Trendsetter platesetter

Platform

 

All Brisque 4.x and 5.x platforms

Operating system

 

IBM AIX 4.3.3 and 5.2


Symptoms

 

After a Brisque 4.x or 5.x cold start or after migrating from Brisque 4.x to Brisque 5.x, there are many retracing occurrences during the expose process on the Trendsetter MPE platesetter.


Cause

 

Configuration settings on the SCSI board revert to their default values after a Brisque cold start or after migrating to Brisque 5.x.


Solution

  To reduce the number of retracing occurrences:
  1. On the Brisque server, select smit > Devices > SCSI Adapter > ChangeShow Characteristics of a SCSI Adapter.
  2. Select the SCSI board that is connected to the platesetter.
  3. Change the settings of the following SCSI parameters:
    • Set Ultra speed on SE bus with external cable to enable.
    • Set Apply change to DATABASE only to Yes.
  4. Reboot the Brisque workstation.

Technical contact(s)
 

Dov Vainer

Submitted by
 

Thom Chadwick

Date submitted
 

03 Aug 2006


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.