Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Dolev800V^3 - Screen shift problem with TSP100

The problem:
With new series of TSP100 board it was discovered a screen shift when exposing to Dolev800V^3.

The solution:
New RBF was created and should be installed on the Brisque Version 4.0.97 + Upd_Brisque4_97_Dolev800V3 only.
The new RBF called screeng.rbf is available on diskette P/N 501V3R604 and it's part of the
510K1R880 - U/G KIT D800V^3 TSP TO TSP100 delivered with every machine.

Loading instructions from the diskette:

  1. Exit the Brisque application.
  2. Login as root and enter your password [ripro].
  3. Insert the diskette into the floppy drive
  4. Type tar -xvf /dev/fd0 and press Enter.
  5. Remove the diskette
  6. Type exit and press Enter to go back to login prompt
  7. Login as cdesci

The screeng.rbf also available on the ftp:
ftp://cilftp.creo.com/pws/brisque/download/V4/Updates/4.0.97/Dolev800V3-4/

Loading instructions from the ftp:

  1. Download/Copy the patch screeng.rbf.tar into the Brisque under dataVolumes (example: /dataVolumes/brisque1.1.0)
  2. Exit the Brisque application.
  3. Login as root and enter your password [ripro].
  4. Type cd /dataVolumes/brisque1.1.0 (location from step 1) and press Enter.
  5. Type tar -xvf screeng.rbf.tar and press Enter.
  6. Type exit and press Enter to go back to login prompt
  7. Login as cdesci

 

 

 


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.