Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


When trying to retrieve a job, it fails with a CRC error


Product

  Prinergy 1.1; Prinergy Connect 2.0

Platform

 

Operating system

 


Error

 


Symptoms

 

When trying to retrieve a job, the process plan fails to retrieve and indicates a CRC (cyclic redundancy check) error on the tape. The rest of the files will not retrieve, even though the process plan is set to "continue on warning or file error".


Cause

  Any hardware fault or environmental problem can cause a hard read error on the tape.


Solution

 

Locate the file that is causing the CRC error in the History log.

Change the process plan to do a selective retrieve without the one that is causing the CRC. The file that having the hard read error cannot be used.

NOTE: There may be multiple CRC errors within one job, and it is very inconvenient and time consuming to retrieve all the files using this workaround.

STRONGLY RECOMMEND THE CUSTOMER TO CREATE A DUPICATE ARCHIVE FOR THEIR JOBS TO AVOID THE POSSIBILITY OF DATA LOSS.

For Prinergy 1.1, create a second archive process plan and ask the customer to archive onto two pools.

For Prinergy 2.0, add the second archive media pools to the archive process plan to ensure the archive goes into two pools. Also, add the archive media pools to the purge process plan, so when purging the job, it will check for the archives in both pools before purging.

Permanent fix:


See also

 


Keywords

 

archiver - retrieve


Technical contact(s)
 

Amy Chan

Submitted by
 

Date submitted
 


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.