Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Prinergy Archiver: To prevent a tape from being written to


Product

  Prinergy 1.1; Prinergy Connect 2.0

Platform

 

Server: Dell or Data General all; Client: PC or Macintosh

Operating system

 

Server: Windows NT or 2000; Client: Windows or Macintosh


Error

 


Symptoms

 

***Applies to Prinergy Connect, Powerpack, Direct, Satellite, depending on installed configuration.***

Preventing a tape from being written to.


Cause

  There is no option in ERSM/RSM or Archiver that allows the tape to be set to read-only status.

Solution

 

To set a tape as read-only, do one of the following:

A. Disable the tape in Archiver Media Manager/RSM. However, to retrieve any job on this tape, the tape must be re-enabled for the retrieve to take effect.

For Prinergy 2.0 only:

B. Create a new media pool for the tape that requires read-only status, move the tape from its existing archive pool to the newly-created one. In this way, the archiver process plan does not contain the newly-created pool and won't ask for the tape to archive. Also, you may want to purge the job before moving the tape to avoid a purging failure or create another purge process plan to make it consistent with the newly-created media pool.

NOTE : Option B is a better way to prevent a tape being written to, as the tape is still enabled and in a separate pool for easy maintenance.

Permanent fix:


See also

 


Keywords

 

archiver FAQs


Technical contact(s)
 

Amy Chan

Submitted by
 

Amy Chan