Multi-file DCS set fails to refine through hot folders in Prinergy 2.2 and 2.3


Product

  Prinergy 2.2, 2.3

Platform

 

Operating system

 


Error

 


Symptoms

 

DCS2 will not process through hot folders. A DCS2 file can be processed outside of a hot folder using the manual "submit file" method.


Cause

  The DCS files were written in upper case, while the pagefile parameter in the EPS control file was written in lower case. Hot folder file names are case sensitive.

Solution

 

Check the EPS control file.

Rename the DCS set files to match the case of the file name.

Permanent fix:


See also

 


Keywords

 

file formats, hot folders, refiner