Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy 3.0.2 | |
Platform |
||
Operating system |
||
|
|
||
Error |
In ppu.log, error message. SQLERRM = ORA-01119: error in creating database file 'J:\ORANT\ORACLE\DATA\AUT1CREO.ORA' |
|
|
|
||
Symptoms |
When running PPU or PUpdate to upgrade Prinergy server from 2.3 to 3.0.2, it fails. However, there is no error on PCheck. |
|
|
|
||
Cause |
An Oracle database file AUT1Creo.ora already existed on the Oracle data folder that causing the script to fail to create the file again. During upgrade process, the script creates this file, however, when the system is reverted back to 2.3, it does not remove this file. |
|
|
|
||
Solution |
Temporary workaround, remove the AUT1Creo.ora file and re-run the upgrade. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
ppu |
|
|
|
||
Technical contact(s) |
Amy Chan |
|
Submitted by |
Amy Chan |
|
Date submitted |
07 June 2005 |
|