Barco PDF from PDF2.1 OUT module fails to Normalize and reports error message.


Product

  2.2.1.9, Prinergy 2.3.1.1

Platform

 

Operating system

 


Error

 

Normalize Error: FILT_LZWTable: Maximum Table size exceeded (missing <CT> code in stream?) while performing normalizing for file:


Symptoms

 

A Barco PDF created by Barco PDF2.1 Out Module fails to Normalize. Files that worked in previous versions (2.2.1.7 for example) will no longer Refine in Prinergy 2.2.1.9 or 2.3.1.1.


Cause

  The LZW decode algorithm was changed for the latest versions of Prinergy to more closely follow the Adobe specification. Previously, the algorithm did not follow the specification as closely and worked OK. This issue is under investigation by Creo and Adobe.

Solution

 

Open the PDF in Adobe Acrobat and save out PostScript. The resulting file will Refine OK. Refined files need to be checked carefully, as this method could have an impact on transparencies and flattening.

Permanent fix:


See also

 


Keywords

 

Barco, file formats, normalizer, refiner


Technical contact(s)
 

Andrew Jinks

Submitted by
 

Stephen Zmetana

Date submitted
 

12 Aug 2004


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.