Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Some staccato screening resolutions at 1200 dpi that ran in Prinergy 2.0.7 are not supported in Prinergy 2.1


Product

  Prinergy Connect 2.1

Platform

 

Operating system

 


Error

 

Staccato screening resolutions of less than 25 dpi when output at a resolution of 1200 dpi fail in Prinergy 2.1.


Symptoms

 

Output proofing fails on selected screens in Prinergy 2.1 , with an error in diag of:

"Could not find screen in screen system Staccato for <xxx> separation, because resolution/ruling not supported."


Cause

  The output group has deemed that only Staccato 25 dpi and higher is a valid screening option for 1200 dpi output. This is enforced for Prinergy 2.1 but was not enforced for Prinergy 2.0.

Solution

 

Resave the staccato screening value in the output process plan with a staccato dpi value of 25 dpi or greater. The output should then run correctly.

Permanent fix:


See also

 


Keywords

 

screening


Technical contact(s)
 

Brian Laberge

Submitted by
 

Brian Laberge

Date submitted
 

07 May 2002


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.