Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


File fails on refine - can't find "Auto Flat Output" process plan


Product

  Prinergy Direct 2.0

Platform

 

Operating system

 


Error

 


Symptoms

 

A file fails when refining, stating that the process plan group "Auto Flat Output" is missing and the process plan "AutoFlatOutput" does not exisit.

Z 03Jul02 08:52:11.230-PDT [3568.3536] SERVER8 ARAXI PTaskD.XCON_Callback TAKS_JobSub.cpp(1370): Register:registering-spe: Process plan D:\PRINERGY\CreoAraxi\data\ProcessPlans\FinalOutput\Auto Flat Output\AutoFlatOutput does not exist.


Cause

  In Prinergy 2.0.4, the "Auto Flat Refining" process plan was one of the Final Output process plans, and was required when using "Treat Input File a Flat". This was a registry setting.

In 2.0.5, it has changed to "Auto Flat Output".

Updating from Prinergy 2.0.4 to 2.0.5 does not update the process plan from "Auto Flat Refining" to "Auto Flat Output" but does update the registery.


Solution

 

Copy the Final Output Process Plan Group "Auto Flat Output" to system drive/Prinergy2.0.4/CreoAraxi/Data/Process Plans/Final Output.

The process plan resides on Betty in the Response Center:

\\Betty\D\Prinergy2.0.4\CreoAraxi\data\ProcessPlans\FinalOutput

Permanent fix: Prinergy 2.0


See also

 


Keywords

 

process plans, refiner


Technical contact(s)
 

Brenda Power

Submitted by
 

Date submitted
 


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.