Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
||
Platform |
Server: Dell or Data General all; Client: PC or Macintosh |
|
Operating system |
Server: Windows NT or 2000; Client: Windows or Macintosh |
|
|
|
||
Error |
||
|
|
||
Symptoms |
***Applies to Prinergy Connect, Powerpack, Direct, Satellite, depending on installed configuration.*** Connecting to a Polaproof 22 x 30, RIP times are very slow - more than half an hour. |
|
|
|
||
Cause |
It should never take longer than 20 minutes to RIP a 4-up DCS from Prinergy, as long as enough RAM is installed (512 MB). The page size is too large in the page setup for the Polaproof (Harlequin) RIP. |
|
|
|
||
Solution |
Make sure the defined page size in the Polaproof (Harlequin) RIP is 21.5" x 28.5", NOT 22" x 29". Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
proofing |
|
|
|
||
Technical contact(s) |
Rob Prior |
|
Submitted by |
||
Date submitted |
||