Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Failure attempting to write the "automatically" generated Preflight Report into the job's PreflightLocalizedReports folder


Product

  Prinergy 2.3.1.2

Platform

 

Operating system

 


Error

 

Could not open the file /Volumes./Jobs on neptune J drive/ImpExpTst/System/PreflightLocalizedReports/002nmex09.p1_rep_17Nov04_en.pdf because it could not be found. Check that the correct server share is mounted on your computer.[1093011]


Symptoms

 

A Refine process plan was created with "automatically" generate Preflight report enabled. The destination folder for the "auto" report is a job's internal System\PreflightLocalizedReports folder.


Cause

  The Preflight internal job folders: System\PreflightReports and System\PreflightLocalizedReports

are not valid targets for the "automatically generate preflight report" folder. Specifying either of those internal job folders as the destination of the "auto" report will interfere with the generation of the internal report. The "auto" report feature is intended as an additional report to generate _outside_ of the job.


Solution

 

Do not specify job-internal folders as the destination for the "automatically" generated Preflight Report.

Permanent fix:


See also

 


Keywords

 

refiner


Technical contact(s)
 

Glen Cairns

Submitted by
 

Glen Cairns

Date submitted
 

09 Dec 2004


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.